NEW QUESTION 38
Click the exhibit button.

A customer's system reported several errors. There was no disruption, but the customer is concerned about the system's health.
Referring to the exhibit, which statement is true?

  • A. One of the IOM modules on shelf 20 has failed.
  • B. Port 1D on the system has failed.
  • C. Storage redundancy is degraded.
  • D. One of the switches has failed.

Answer: C

 

NEW QUESTION 39
Your customer added a new DS2246 shelf to an existing stack on their FAS8060A system. The customer then noticed that the new shelf's disks appear with the shelf serial number instead of the shelf ID in the sysconfig -r command output.
What is the reason for this problem?

  • A. The ACP is cabled incorrectly.
  • B. The new shelf has the same ID as another shelf.
  • C. There is failed IOM module in the new shelf.
  • D. The SAS is cabled incorrectly.

Answer: D

 

NEW QUESTION 40
Click the exhibit button.


Many end users are complaining that logging in their systems takes a long time. When the login to the desktop finishes, everything is fine. The home directories are on NetApp storage. You do not see any significant disk or CPU contention on the controller, so you gather output statistics from the controller and focus on SMB.
Referring to the exhibit, which two actions would help diagnose the problem? (Choose two.)

  • A. Engage your desktop team to collect network traces from the clients.
  • B. Collect more statistics to determine whether the controller itself is causing latency.
  • C. Engage your Windows team to make sure that the domain controllers are not overloaded.
  • D. Engage your network team to make sure that there are no issues between the storage controller and the domain controller.

Answer: B,D

 

NEW QUESTION 41
Click the exhibit button.

When you log in to a node, a warning is displayed as shown in the exhibit.
Which statement is correct in this scenario?

  • A. One or more RDB db files are damaged due to an internal software error.
  • B. The node cannot communicate with the rest of the nodes in the cluster.
  • C. The node root volume was moved to a new aggregate.
  • D. The partner still hosts the CFO aggregate for the node.

Answer: B

 

NEW QUESTION 42
A customer reports that a takeover has been disabled on an HA pair.
What would be a cause for this to happen?

  • A. The cluster network is not functioning properly.
  • B. The interface for the hardware assist has become unavailable.
  • C. There is a disk running too hot.
  • D. The HA interconnect is not functioning properly.

Answer: D

 

NEW QUESTION 43
A field support engineer has just replaced the IOXM on NODE2 on a FAS8080 running ONTAP 9.1. After the replacement, the customer is unable to perform a giveback because the interconnect is down.
In this scenario, which statement is correct?

  • A. Verify that the interconnect cables on the IOXM are connected correctly.
  • B. Verify that there cross-links between the interconnects.
  • C. Verify that the interconnect cables on the motherboard are connected correctly.
  • D. Verify that the installed FC-VI cards are configured properly.

Answer: A

 

NEW QUESTION 44
Click the exhibit button.

A storage administrator reports that when they enabled Vscan, they began receiving reports of CIFS users having very slow access to all their files. The storage administrator recovered from the issue by disabling Vscan on their SVM. The storage administrator was able to collect perfstat output during the time of the reported slow access, as shown in the exhibit.
In this situation, what is the problem?

  • A. The problem is on the SVM, as shown in the scan_latency output.
  • B. Vscan server 192.168.100.144 was slower than Vscan server 10.23.23.54 in completing Vscan requests.
  • C. The problem was with both Vscan servers 192.168.100.144 and 10.23.23.54.
  • D. Vscan server 10.23.23.54 was slower than Vscan server 192.168.100.144 in completing Vscan requests.

Answer: B

 

NEW QUESTION 45
You configured iSCSI multipathing on a Windows host to a 2-node ONTAP cluster so that you can attach to some LUNs. You see that the host logging in to both iSCSI LIFs in the ONTAP cluster, and you notice that the igroup is correctly set. After you open Disk Management and rescan for disks, the NetApp LUNs do not show up.
In this scenario, what should be performed to enable the LUNs to be visible to the Windows host?

  • A. Set up Selective LUN Mapping (SLM) and try scanning again.
  • B. Configure the ONTAP nodes for HA and try scanning again.
  • C. Set up LUN mapping and try scanning again.
  • D. Configure the SVM for FCP and try scanning again.

Answer: A

 

NEW QUESTION 46
A customer mentions that their intercluster SnapMirror replication operations consistently take much longer than normal. While troubleshooting, you want to initiate a test SnapMirror session to collect performance data.
How would you accomplish this task?

  • A. Run the network test-path command to simulate a SnapMirror connection and record the latency/throughput data.
  • B. View the active network connections to the node to see if there a large number of active connections.
  • C. Use the ifstat command to collect network performance data for the physical interface.
  • D. Run the network statistics lif show command for the intercluster LIF to simulate a network connection.

Answer: A

 

NEW QUESTION 47
Your customer states that the storage efficiency on their FAS 8200 is far below what they had expected for a VMware NFS datastore. They enabled deduplication three days ago. The job ran every night for only 10-20 minutes, and the space savings now is less than 5%.
What is causing the space savings to be so low?

  • A. They have enabled aggregate-level inline data compaction, so the savings are at the aggregate level.
  • B. They have not enabled volume-level compression.
  • C. They have enabled aggregate-level inline deduplication, so the savings are at the aggregate level.
  • D. They have not run a baseline deduplication to scan old data.

Answer: B

 

NEW QUESTION 48
A reboot was performed by a watchdog reset on the node.
In this scenario, which statement is true?

  • A. In case of an L2 watchdog event, determine whether a core was dumped.
  • B. The wafl_check command should be executed.
  • C. The service processor no longer responds.
  • D. In case of an L1 watchdog event, determine whether a panic message was recorded.

Answer: C

 

NEW QUESTION 49
The error message shown below is reported in the EMS log file.
"[sis.changelog.full:warning]: Change logging metafile on volume DATA1 is full and can not hold any more fingerprint entries." What are two ways to solve this problem? (Choose two.)

  • A. Increase the size of the changelog to allow the operation to continue.
  • B. Modify the threshold that triggers a deduplication operation.
  • C. Clear the changelog manually so that the operation can restart.
  • D. Modify the storage efficiency policy so that deduplication runs more frequently.

Answer: A,B

 

NEW QUESTION 50
In a 4-node cluster, nodes 1 and 2 are an HA pair, and nodes 3 and 4 are an HA pair. The following error appears in the log.
12/15/2018 15:48:47 node-2CRITICALclam.node.ooq: Node (name=node- 2, ID= 1001) is out of "CLAM quorum" (reason =quorum update).
In this scenario, which two statements are correct? (Choose two.)

  • A. Node 2 takes over node 1.
  • B. All LUNs are online in the cluster.
  • C. Node 1 takes over node 2.
  • D. All LUNs are offline in the cluster.

Answer: C,D

 

NEW QUESTION 51
You want to determine which SMB versions that a CIFS server can use when communicating with external servers.
Which two CIFS server settings should be reviewed to accomplish this task? (Choose two.)

  • A. smb1-enabled
  • B. smb2-enabled
  • C. smb1-enabled-for-dc-connections
  • D. smb2-enabled-for-dc-conections

Answer: A,D

 

NEW QUESTION 52
Click the exhibit button.

Your customer has severe latency on one of their SATA aggregates. You run the statit -b and statit -e commands to obtain detailed disk statistics.
Referring to the output shown in the exhibit, which disk would be the problem?

  • A. 0a.11.19
  • B. 0a.11.21
  • C. 0a.11.23
  • D. 0a.13.21

Answer: A

 

NEW QUESTION 53
Click the exhibit button.

A customer reports that storage latency has recently increased substantially. No changes have been introduced, and the traffic did not change.
Referring to the output shown in the exhibit, which corrective step should be taken?

  • A. Move some volumes off the affected aggregate.
  • B. Add more spindles.
  • C. Throttle the client traffic.
  • D. Perform the volume reallocation.

Answer: C

 

NEW QUESTION 54
Click the exhibit button.

You have just cabled a new shelf to a FAS8200. Running the system node run -node * sysconfig - a command indicates that multipath HA is configured. However, after running Config Advisor, you receive an error that your cabling is incorrect.
As indicated in the exhibit, which two actions will correct the cabling? (Choose two.)

  • A. Move the 0b SAS connection on the top controller to 0d on the top controller.
  • B. Move the 0b SAS connection on the bottom controller to 0d on the bottom controller.
  • C. Move the 0b SAS connection on the top controller to 0d on the bottom controller.
  • D. Move the 0b SAS connection on the bottom controller to 0d on the top controller.

Answer: A,B

 

NEW QUESTION 55
Click the exhibit button.

A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.
Referring to the exhibit, which statement is correct?

  • A. The problem is due to a difference in operation size.
  • B. Perfstat should be used to explain the behavior.
  • C. A case with NetApp should be raised to find the root cause.
  • D. There are operation types that are not listed in the output.

Answer: A

 

NEW QUESTION 56
Click the exhibit button.

A customer has an FC SAN with brocade switches. Each server attached to the SAN gas four FC ports. The customer describes that one of their servers has only four paths to the LUNs configured on the cluster. There should be eight paths on all the other servers. The switch administrator has verified the zone configuration.
Referring to the exhibit, which two actions would you perform to troubleshoot the problem? (Choose two.)

  • A. Review the LIF configuration on the cluster.
  • B. Review that the host side FC link ports are enabled.
  • C. Review the driver version on the server.
  • D. Review the igroup configuration on the cluster.

Answer: A,C

 

NEW QUESTION 57
End users are complaining of high latency when accessing an ONTAP 9 luster.
Which command helps you to determine whether there is a storage component that is contributing to this problem?

  • A. qos statistics latency show
  • B. sysstat -c 30 -M 1
  • C. wafltop show -v -cpu -I 10 -c 5-n 6
  • D. qos statistics performance show

Answer: D

 

NEW QUESTION 58
Click the exhibit button.

You are investigating an AutoSupport Disk Redundancy Failed alert. Cluster A lost connectivity to storage bridge BrB1, while cluster B lost connectivity to storage bridge BrA1.
Referring to the exhibit, which three components need investigation? (Choose three.)

  • A. storage bridges BrB1
  • B. FC switch SwA1
  • C. FC switch SwB1
  • D. FC switch SwA2
  • E. ISL cables

Answer: B,C,E

 

NEW QUESTION 59
......